Test Analysis of the Shockproof Reinforcement of Seismometers in Earthquake Observation Station Standardization

XIAO Wu-jun1, ZHAO Nan2, LI Xiao-jun3, ZHAO Gang4, LIU Quan5, QU Li6, LUO Jia-ji2   

  1. 1. China Earthquake Networks Center, Beijing 100045, China;
    2. Anhui Earthquake Agency, Hefei 230031, China;
    3. Hebei Earthquake Agency, Shijiazhuang 050021, China;
    4. National Institute of Natural Hazards, Beijing 100085, China;
    5. The Institute of Engineering Mechanics, CEA, Haerbin 150080, China;
    6. Shandong Earthquake Agency, Jinan 250014, China
  • Received:2020-04-28 Revised:2020-08-31 Online:2021-10-31 Published:2022-03-25

Abstract: In this paper, according to the requirements of earthquake observation stations standardization for the shockproof reinforcement of seismometers and other professional equipment. After the seismic sensors are equipped with shockproof reinforcement devices, the shaking table test and the consistency analysis of the stations observation data are carried out. In the shaking table test, the results show that when the PGA of the seismometer is greater than 103.2 cm·s-2, the seismometer has obvious displacement. So it is recommended to install shockproof reinforcement device where the area with intensity is greater than Ⅶ. In the process of consistency analysis, we use the square coherence method to compare the near earthquake and far earthquake records in the frequency domain and time domain, the results show there is no significant difference in the consistency of seismometer system between the sensor with shockproof reinforcement device and without.

Key words: Seismometer, Shockproof device, Vibration table, Test