Welcome to EARTHQUAKE,

EARTHQUAKE ›› 2022, Vol. 42 ›› Issue (3): 204-215.doi: 10.12196/j.issn.1000-3274.2022.03.015

Previous Articles    

The Observation System Failure Analysis of the Anomaly Verification of Deformation

MA Dong1,2, QU Man1,2 , HOU Xiao-zhen1,2, GAO Chen1,2, NIU Shu-yu1,3, ZHAO Hui-qin1,4   

  1. 1. Hebei Hongshan National Observatory on Thick Sediments and Seismic Hazards, Xingtai 054000, China;
    2. Earthquake Administration of Hebei Province, Shijiazhuang 050021, China;
    3. Shijiazhuang Earthquake Monitoring Center Station, Shijiazhuang 050021, China;
    4. Baoding Earthquake Monitoring Center Station, Baoding 071000, China
  • Received:2021-07-23 Revised:2021-08-05 Online:2022-07-31 Published:2023-03-29

Abstract: The anomaly verification reports of deformation from 2013 to 2020 were collected. The observation failures in these reports were statistically analyzed and classified. The failures can be divided into 7 categories, including instrument main failure, power supply and signal line failure, data collector failure, preamplifier and scale value failure, calibration system failure, coupled problem, instrument pier problem, respectively. Among them, the main problems are instrument main failure, power supply and signal line failure and scale value failure. This paper exhibits detailed examples about various observation system types, analyzes data variations caused by kinds of observation system failures, and suggests solutions.

Key words: Deformation observation, Anomaly verfication, Observation system failure, Calibration, Scale value

CLC Number: