欢迎访问《地震》,

地震 ›› 2022, Vol. 42 ›› Issue (2): 52-62.doi: 10.12196/j.issn.1000-3274.2022.02.004

• • 上一篇    下一篇

力平衡反馈石英水平摆倾斜仪传递函数测试方法研究

姜沣1, 高尚华1, 薛兵1, 李际弘2   

  1. 1.中国地震局地震预测研究所, 北京 100036;
    2.中电科海洋信息技术研究院有限公司, 北京 100041
  • 收稿日期:2020-07-20 修回日期:2020-08-28 出版日期:2022-04-30 发布日期:2023-02-17
  • 通讯作者: 高尚华, 研究员。 E-mail: gao966@ief.ac.cn
  • 作者简介:姜沣(1995-), 男, 山东青岛人, 在读硕士研究生, 主要从事地震观测仪器测试研究。
  • 基金资助:
    中国大陆综合地球物理场观测仪器研发专项(Y201804); 中国地震局地震预测研究所基本科研业务费专项(2018IEF0203, 2019CSES0101); 国家重点研发计划专题(2018YFC1503904-06)

Measurement of the Data Transfer Function of the Force Balance Feedback Quartz Horizontal-pendulum Tiltmeter

JIANG Feng1, GAO Shang-hua1, XUE Bing1, LI Ji-hong2   

  1. 1. Institute of Earthquake Forecasting, CEA, Beijing 100036, China;
    2. CETC Ocean Information Co., LTD, Beijing 100041, China
  • Received:2020-07-20 Revised:2020-08-28 Online:2022-04-30 Published:2023-02-17

摘要: 基于力平衡反馈技术, 利用阶跃电压信号和正弦波电压信号作为标定信号, 提出了一种石英水平摆倾斜仪传递函数的动态测试方法。 本文研究了标定电压信号的引入方法, 推导了力平衡反馈石英水平摆倾斜仪对输入标定电压信号的传递函数及其输出表达式, 并进行了测试试验, 得到倾斜仪的正弦标定输出响应和阶跃标定输出响应; 在此基础上, 应用推导的理论公式, 对正弦标定输出响应和阶跃标定输出响应分别进行非线性拟合, 得到力平衡反馈石英水平摆倾斜仪的周期和阻尼。 试验测试结果显示, 正弦波标定测试得到的周期和阻尼与阶跃标定测试得到的周期和阻尼一致性较好, 验证了本文所提出测试方法的有效性。

关键词: 力平衡反馈技术, 石英水平摆倾斜仪, 传递函数, 测试方法

Abstract: This paper presents a method to dynamically test the data transfer function of the quartz horizontal-pendulum tiltmeter by using step voltage signal and sine wave voltage signal as calibration signals. We firstly introduced the addition way of the calibration signals to the tiltmeter and derived the expressions of the transfer function and the outputs of force balance feedback quartz horizontal-pendulum tiltmeter when calibration signals were input. Afterward, we performed test experiments and got the tiltmeter' s output responses of the sinusoidal calibration and the step calibration. Based on the above-mentioned test results and using the derived theoretical formula, we carried out nonlinear fitting of sinusoidal calibration output response and step calibration output response respectively, and obtained the period and damping of the force balance feedback quartz horizontal-pendulum tiltmeter according to the fitting results. The laboratory test results show that the period and damping obtained by sine wave calibration test are in good consistent with those obtained by step calibration test, which verifies the effectiveness and consistency of the test method presented in this paper.

Key words: Force balance feedback technique, Quartz horizontal-pendulum tiltmeter, Data transfer function, Measurement method

中图分类号: